I. Product Overview
II. Application Features
- The hard flat membrane probe structure is particularly suitable for measuring the pressure of viscous media, avoiding measurement errors caused by medium blockage in the cavity.
- Different structures of the hard flat membrane probe adapt to various complex working conditions, enhancing the product's reliability and overload resistance.
- High-precision strain measurement technology is adopted to ensure accurate pressure measurement.
III. Structure and Working Principle
IV. Operating Environment
- Ambient temperature: -30~70℃;
- Relative ambient humidity: ≤90% (25℃);
- Atmospheric pressure: 80~106KPa;
- Can be used in environments with combustible and explosive gases such as coal dust and gas;
- Free from strong vibration and impact;
- Suitable for measuring the pressure of various liquids, gases, powders, slurries, etc., that are compatible with the contact medium materials.



Main technical parameters for general applications
Basic range | 0 ~ 0.3 ···150MPa |
Overload | Full scale less than100When MPa is 1.5 times the full scale pressure, Full scale greater than or equal to100When MPa is 1.2 times the full scale pressure |
Burst pressure | Full scale less than100When MPa is Twice the full scale pressure, Full scale greater than or equal to100When MPa is 1.5 times the full scale pressure |
Accuracy | 0.1%FS 0.2%FS 0.25%FS 0.3%FS 0.5%FS 1%FS |
Operating temperature range | -20℃~70℃ |
Temperature compensation range | -20℃~60℃ |
Stability | ≤±0.2%FS |
Supply voltage | 12 ~ 32VDC (typical value)24VDC) |
Output signal | 4~20mA(Two-wire system),0.5~4.5VDC, 0~10VDC, 0.25~2.5VDC, 0~5VDC, RS485 , RF , MV sensor raw signal |
Insulation resistance | 500MΩ/250VDC |
Protection level | IP67 |