I. Overview of ES Series Sensor Cores
II. Operating Environment of ES Series Sensor Cores
- Ambient temperature: - 30~70℃;
- Relative ambient humidity: ≤90% (at 25℃);
- Atmospheric pressure: 80 - 106 KPa;
- Without strong vibration and impact;
- Measurement of the pressure of various liquids, gases, powders, slurries, etc. that are compatible with the contact medium materials.
Basic common parameter indicators of ES series sensor core
basic range | 0 ~ 0.3 ···150MPa··300MPa |
overload | full scale less than 100at MPa 1.5 times the full-scale pressure, full scale greater than or equal to 100at MPa 1.3 times the full-scale pressure |
destruction pressure | full scale less than 100at MPa 2 times the full-scale pressure, full scale greater than or equal to 100at MPa 1.5 times the full-scale pressure |
accuracy | 0.1%FS 0.2%FS 0.25%FS 0.3%FS 0.5%FS 1%FS 2%FS |
operating temperature range | -30℃~70℃ |
temperature compensation range | -20℃~60℃ |
stability | ≤±0.2%FS |
supply voltage | 0 ~ 12VDC |
sensitivity | 1.0±0.3mV/V |
insulation resistance | 500MΩ/250VDC |
impedance | 1000±100Ω; 2200±100Ω |
zero output | ±0.5%FS |
zero drift | ±0.5%FS/10℃ |
explosion-proof type | mining intrinsically safe type |
enclosure protection level | IP54 |